UFx.py version 2.1 from 10/19/2018
Page 1 of 2
Created by user vjeran on 10/19/2018 16:41:29
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Background |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Background\Stretched Wire HXR\DATASET0001\Final Results\Stretched Wire |
Date : | 08-29-2018 |
Time : | 12:06:08 - 13:15:02 |
Operator : | VV |
Project : | LCLS-II |
Device Type : | Phase Shifter |
Run Number : | 1 |
Data Type : | |
Run Comment : | HXR measurement situation |
gap | I1Y | I2Y | I1X | I2X |
- |
-10.0 0.4 (5) |
-2.7 0.4 (5) |
10.6 2.0 (5) |
3.4 4.6 (5) |
integral | gap | -02.00;+00.00 | -01.00;+00.00 | +00.00;+00.00 | +01.00;+00.00 | +02.00;+00.00 |
I1Y |
- |
-9.7 0.6 (3) |
2.7 1.0 (3) |
-5.9 6.8 (3) |
-1.5 8.1 (3) |
-1.5 7.7 (3) |
I2Y |
- |
-2.6 0.2 (3) |
-0.1 0.1 (3) |
-1.7 1.5 (3) |
-0.9 1.3 (3) |
-0.8 1.5 (3) |
I1X |
- |
11.8 0.8 (3) |
11.1 1.1 (3) |
12.2 0.2 (3) |
11.0 0.9 (3) |
11.5 1.3 (3) |
I2X |
- |
1.2 0.5 (3) |
1.1 0.5 (3) |
1.4 0.5 (3) |
1.0 0.3 (3) |
1.4 0.5 (3) |
integral | gap | +00.00;-02.00 | +00.00;-01.00 | +00.00;+00.00 | +00.00;+01.00 | +00.00;+02.00 |
I1Y |
- |
-9.6 0.8 (3) |
-10.3 0.7 (3) |
-10.0 1.1 (3) |
-9.8 0.6 (3) |
-9.8 1.1 (3) |
I2Y |
- |
-2.7 0.2 (3) |
-2.5 0.2 (3) |
-2.8 0.1 (3) |
-2.6 0.4 (3) |
-2.6 0.2 (3) |
I1X |
- |
11.9 0.7 (3) |
7.4 0.1 (3) |
10.7 2.8 (3) |
8.9 2.6 (3) |
9.0 2.6 (3) |
I2X |
- |
1.2 0.2 (3) |
0.8 0.4 (3) |
1.1 0.2 (3) |
0.7 0.4 (3) |
1.2 0.2 (3) |
UFx.py version 2.1 from 10/19/2018
Page 2 of 2
Created by user vjeran on 10/19/2018 16:41:29
SLAC Moving Stretched Wire Magnetic Field Measurement Summary
Magnet ID : | Background |
Directory : | S:\magdata\LCLS-II\Phase Shifter\Background\Stretched Wire HXR\DATASET0001\Final Results\Stretched Wire |